Carrier 48fc 15 ton.

Item: 48FCEM07A2A50A0A0. Carrier 6 Ton, 11.0 EER Package RTU Medium Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3. MFR: Item: 48FCEM07A2A60A0A0. Carrier 7.5 Ton, 11.2 EER Package RTU Medium Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,208/3. MFR: Item:

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Carrier 48GC Series Pdf User Manuals. View online or download Carrier 48GC Series Installation Instructions ... Gas Heat (48FC and 48GC) 8. Controls Quick Set- -Up. 8. Control Set Point and Confirmation Log. 8. Initial Startup. 8. ... Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector ... The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include: 48TCFD24A2A5-6F0G0 - 20 TON High Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU; Documents. 48-50fc-20-30-01pd; 48fc-20-30-01si_rev_b; Specifications. Brand Carrier; Availability Available for Delivery; Warehouse Availability MALD; Equipment Type Commercial Packaged Outdoor Unit; Gas Stages 2 …Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ...With solutions from 10 through 500 tons, screw or scroll, Carrier air-cooled chillers are the best choice for your needs. With a wide range of air-cooled chiller scroll and screw types, capacities (10 to 500 tons) and sustainable refrigerant options, Carrier is a leader in the industry. Whether it be non-ozone depleting refrigerant, simple ...

View and Download Carrier 48FC installation instructions online. Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. 48FC air conditioner pdf manual download. Also for: 48gc, 48hc, 48lc, 48tc, 582k, 581k, 581j, 580j,... 48TCED14A2A6-0A0A048 = Gas Heat Packaged RooftopTC = WeatherMaker™ Standard EfficiencyE = Medium HeatD = Two Stage Cooling Models 08-1614 = 12.5 tonsA = None2 = Belt Drive, Medium Static OptionA = Al/Cu - Al/Cu6 = 460/3/600 = Electromechanical Controls ca

Features. Options. Physical Data. Documents. Performance Features. ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82% …The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include:

42 Series AirStream™ Fan Coils. 42BH Family REVIT file. 42BV Family REVIT file. 42CA Horizontal Furred-In Family REVIT file. 42CE Horizontal Furred-In with Plenum Family REVIT file. 42CF Horizontal Furred-In, High Static Family REVIT file. 42CG Horizontal Cabinet Family REVIT file. 42CK Horizontal Cabinet, Ducted Family REVIT file.Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: Single cooling stage models are available from 3 -- 10 ton. Two cooling stage models are available from 7.5 -- 15 ton. SEER up to 13.0. (up to 13.4 with ECM motor) EER's up to 11.1. (up to 11.4 with ECM motor) 12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; BTU Input 250000; 14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

Sasha 402 twitter

8.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM09A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 09 = 8.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …

A short ton is equal to 2,000 pounds and a long ton is 2,240 pounds. However, there are different types of tons, depending on the country. In the United States, the ton most common...Supply Width 15.52 Return Length 37.921 Return Width 15.799 RW RL SW SL CW CL Table 5. Curb matrix Type Trane Lennox Carrier Bryant JCI/York ICP Heil Day and Nigh Goodman Daikin Older Voyager Gas/Electric GCC036-060 ZGB 036-060 48DJ 004-00, 48GJ 006 48HC 004-006, 48HE 004-006 48HJ 004-006, 48KC 004-006 48LJ 004-006, …7.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM08A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 08 = 7.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP. Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt ...

10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48fc-8-14-01si ; 48fcem 10t 208-230-3 ... Specifications. Brand ...Documents Details. WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology. 48FC. Type: Gas heat. Capacity Range (Tons): 3 - 27.5. Efficiency …50FCQ 04 -28, 50GCQ 04-06 Single Package Rooftop Heat Pump Units with SystemVuTM Controls Version 3.X and Puron R-410A Refrigerant Controls, Start-Up, Operation and Troubleshooting Instructions IMPORTANT: This literature covers 50FCQ 04 -28 and 50GCQ 04-06 models with SystemVu controls version 3.X...is proprietary to carrier corporation and shall not be used or disclosed to others, in whole or in part, ... - 48fc packaged rooftop gas heating/electric cooling units - 14 seer 3, 4, 5 tons, 15 ieer 6 ton . project: ~untitled1 09/19/2020 prepared by: 12:13pm ... Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480371-01 Printed in U.S.A. Form 48FC-16-01SI Rev. A Pg 1 7-22 Replaces: New. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies are Carrier West Training – HVAC Training

When it comes to finding the perfect fifth wheel for your needs, there are a few key factors to consider. Fifth wheels are a great option for those who want to enjoy the comforts o...Air Conditioner Carrier 48FC Installation Instructions Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48LJ Installation, Start-Up And Service Instructions Manual

View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download. ... Page 75 APPENDIX B — PHYSICAL DATA (cont) 48FC*(M,N)16 — 15 Ton — Physical Data ...NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Two-stage cooling capacity control on all models. SEER to 16.0. Gas efficiencies up to 82%. Cooling operating range up to 125 °F (52°C) and down to 35°F (2°C) Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ... Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting (144 pages) Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant. Table of Contents General. Manual is suitable for 4 more products: 48GC Series 48GC 05 48GC 04 48GC 06. Brand: Carrier | Category: Air Conditioner | Size: 4.05 MB.48 50FC 8 16 01PD Carrier Nominal 10 Ton 11 2 EER Package RTU Cooling Only Two Stage 208 3 siglers mw link id 10646 ||| Product Data WeatherMaker Single Packaged Rooftop 7.5 to 15 Nominal Tons 2023 Carrier 48/50FC**08, 09, 12, 14, 16 48FC: Single-Package Gas Heating/Electric Cooling Rooftop Units 50FC: Electric Cooling Rooftop …Carrier’s new Gas Heat/ Electric Cooling WeatherExpert® 6 to 10 ton commercial packaged rooftop models are designed to provide total low cost of ownership by providing some of the highest cooling efficiencies in the industry, with low installed costs, low maintenance costs, and high reliability. These models focus on providing highNEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C)

Hinds county tag estimator

Choosing the right AC brand from so many options can be daunting. Our Carrier air conditioner review can help you decide if it's a good fit for your home. Expert Advice On Improvin...

The price for a ton of coal varies greatly depending on what kind of coal it is. According to the U.S. Energy Information Administration, the average price for coal in 2012 was $39...Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES AND BENEFITS. Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)48TC*D/E units for installation in the United States contain use of Carrier's Staged Air Volume (SAV™) 2-speed indoor fan control system. This complies with the U.S. Department of Energy (DOE) efficiency standard of 2018. ... Fig.15 (size 08-16) for base rail details. See Fig. 6 (size 07) for thru-the-base charts.Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES AND BENEFITS. Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor) Carrier Carrier6 to 23 Nominal Tons. 50LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have the some of the industry’s highest IEERs available. The multi stage cooling compressor allows for added comfort, energy savings and humidity control.38AU Gemini™ Commercial Split-System Air-Cooled Condensing Units & 40RU Air Handling Units. 38AUD 10-12 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 15 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 20 Ton Packaged Air Cooled Condenser Units, Dual …Carrier air conditioners, for example, offer a variety of energy efficiency or SEER2* ratings, various types of comfort-enhancing technologies and even sound ratings. Installed costs might range from anywhere between $3,000 to $15,000 or more.Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP. Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt ...

Permanently lubricated evaporator-fan motor. Totally enclosed condenser motors with permanently lubricated bearings. Low pressure and high-pressure switch protection. …Carrier 48fc 10 Ton, Carrier Commercial Packaged Outdoor Units Melrose Park, IL, WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology ... 2023-12-24; 2023-12-23; 2016-02-15; 2012-12-24; 2016-01-28; 2015-09-27; 2022-10-19; carrier 48fc 10 ton. RTU Curb Adapters Welded Curb Adapters Curbco. Carrier 48FC …10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48fc-8-14-01si ; 48fcem 10t 208-230-3 ... Specifications. Brand ...Instagram:https://instagram. kiava swim promo code Choosing among a broad range of air conditioner brands can be overwhelming. So we've narrowed it down to two brands, YORK® and Carrier, to help you decide. Expert Advice On Improvi... Item: 48FCEM07A2A50A0A0. Carrier 6 Ton, 11.0 EER Package RTU Medium Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3. MFR: Item: 48FCEM07A2A60A0A0. Carrier 7.5 Ton, 11.2 EER Package RTU Medium Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,208/3. MFR: Item: dry cleaners in kingman az Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup- SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. charles lawson pastor wiki 6 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... mills county scanner 14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only internapure Carrier6 2 15.0 74 x 47 x 41 67 110 150 607 Gas Heating / Electric Cooling Models – 48FC Electric Heat / Electric Cooling & Cooling Only Models – 50FC Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) IEER Dimensions (in) L x W x H Electrical Heat Nominal kW Range Approx. Unit Weight (lbs) 3 1 (14.0) 74 x 47 x 33 4.0 to 15.0 437 5 3 bank louisville ky Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 460-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F … kel tec p17 holster 04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger With so many cell phone carriers to choose from, it can be difficult to determine which one is the best fit for you. The first step in finding the right cell phone carrier is to ev... 12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM14A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... sc ready reading practice test View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download. ... Page 75 APPENDIX B — PHYSICAL DATA (cont) 48FC*(M,N)16 — 15 Ton — Physical Data ...When it comes to finding the perfect fifth wheel for your needs, there are a few key factors to consider. Fifth wheels are a great option for those who want to enjoy the comforts o... directv this location not authorized 48FC 08-14 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society of Heating, Refrigerating, and Air ... leon harris annual salary 48TCED08A2A5-0A0G0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU; 48TCEM08A2A5-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU mychart lakelandhealth 48TCED14A2A6-0A0A048 = Gas Heat Packaged RooftopTC = WeatherMaker™ Standard EfficiencyE = Medium HeatD = Two Stage Cooling Models 08-1614 = 12.5 tonsA = None2 = Belt Drive, Medium Static OptionA = Al/Cu - Al/Cu6 = 460/3/600 = Electromechanical Controls caView and Download Carrier 48FC M20 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 17.5-27.5 Nominal Tons. 48FC M20 Series air handlers pdf manual download. Also for: 48fc n20 series, 48fc m24...Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time; Field convertible from vertical to horizontal airflow for slab mounting (sizes 04-16) Provisions for thru-the-bottom power entry capability as standard; Dedicated vertical and horizontal airflow models available (sizes 17 to 30 only)